Mostrar el registro sencillo del ítem

Structural design of Bellamare building

dc.contributor.advisorArteta Torrents, Carlos Alberto
dc.contributor.authorCurvelo Montenegro, Yohel Hassid
dc.contributor.authorRodríguez Vanegas, Moisés
dc.contributor.authorMovilla Armella, José Alejandro
dc.date.accessioned2022-12-06T16:45:42Z
dc.date.available2022-12-06T16:45:42Z
dc.date.issued2022-12-05
dc.identifier.urihttp://hdl.handle.net/10584/11213
dc.description.abstractEl edificio Bellamare ubicado en la ciudad de Santa Marta, es una edificación de condición residencial, construida con el fin de cubrir la necesidad de generación viviendas, esto tendría como consecuencia que los habitantes del edificio estén seguros y se pueda garantizar la calidad de vida. El proyecto tiene como objetivo producir un diseño estructural que cumpla con las especificaciones constructivas adecuadas, a partir del modelo estructural establecido. La rúbrica de evaluación del entregable final de este proyecto, está ligada a parámetros estructurales, constructivos y financieros, esto indicará cual es la mejor alternativa estructural del proyecto. El sistema estructural para diseñar es un sistema combinado, con pórticos y muros estructurales con disipación de energía moderada (DMO) con losa maciza en dos direcciones sobre vigas maestras con un sistema de vigas intermedias, capaces de resistir amenaza sísmica intermedia. El edificio cuenta diferentes losas tipos que son el lobby que está sobre un semisótano, 6 pisos de apartamentos residenciales, un cuarto de máquinas y por último una cubierta. En el desarrollo del modelo estructural se presentan limitantes como derivas que implican redimensionamiento de los miembros resistentes a sismos. Como norma de diseño se usó la NSR -10, tomando como complemento la guía ACI 318-14. Como finalidad se crea un diseño óptimo para la construcción del edificio.es_ES
dc.description.abstractThe Bellamare building located in Santa Marta city is a residential building constructed to cover the need for housing generation. This status will grant the residents in the building safety and will guarantee a quality of life. The project aims to display a structural design that satisfies the relevant constructive specs from the established structural model. The evaluation rubric of the final essay of this project is attached to structural, constructive, and financial parameters, which will indicate the best structural alternative for the project. The structural system to design is a combined scheme using portico and load-bearing walls with moderate energy dissipation capacity (DMO) that follows the ACI CODE 318-14: Building Code Requirements for Structural Concrete. It will also have two-directional concrete slabs on supporting beams with a system of intermediate beams able to bare the intermediate seismic risk. The building has a variety of slabs that lay on a basement, six residential stories, a machine room, and roofing. The development of the structural model poses some limitations that require resizing the seismic-resistant structural members. The Colombian construction code NSR-10 was used as a guide for the design of the structural model, along with the American Concrete Institute code ACI 318-14 presenting an optimum design for the construction of the building.es_ES
dc.language.isospaes_ES
dc.publisherBarranquilla, Universidad del Norte, 2022es_ES
dc.rightsUniversidad del Nortees_ES
dc.subjectDiseñoes_ES
dc.subjectSismoes_ES
dc.subjectNSR - 10es_ES
dc.subjectDerivases_ES
dc.subjectEdificaciónes_ES
dc.titleDiseño estructural edificio Bellamarees_ES
dc.titleStructural design of Bellamare buildingen_US
dc.typearticlees_ES
dc.rights.accessRightsopenAccesses_ES


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem