    Sistema estructural basado en muros de carga para el edificio de ciencias e idiomas Mario Santo Domingo

    Structural system based on load-bearing walls for the Mario Santo Domingo science and language building

    • Exportar citas
      • Exportar a Refworks
      • Exportar a Ris
      • Exportar a Endnote
      • Exportar a Mendeley
    URI
    http://hdl.handle.net/10584/10682
    Registro completo
    Mostrar el registro completo del ítem
    Autor
    Sepúlveda Almarales, Víctor Hugo
    Prasca Atencia, Ana María
    Bertel Ibarra, Sebastián Camilo
    Andrade Paredis, Andrés Felipe
    Fecha
    2022-06-03
    Resumen
    El edificio Mario Santo domingo se encuentra ubicado en el kilómetro 5 vía Puerto Colombia dentro de las instalaciones de la Universidad del Norte. Este edificio pretende suplir la necesidad aumentar la planta física de dicha universidad. El sistema constructivo de la propuesta se basa en muros de carga resistentes a momento con capacidad de resistir la carga axial demandada por el uso y constitución del edificio, además de un pórtico no resistente a momento pero que es capaz de transmitir cargas hacia la cimentación. El sistema se diseñó para una capacidad moderada de disipación de energía DMO, y suponiendo una zona de amenaza sísmica intermedia, usando los datos de coeficiente que representa la aceleración y velocidad horizontal pico efectiva correspondientes a la ciudad de Santa Marta. Para el análisis de la carga sísmica, se calculó el peso sísmico de todos los elementos de la estructura y las fuerzas horizontales que serían provocadas por un eventual sismo y se determinó que la estructura es capaz de disipar un 7,8% de su peso. En total la estructura requiere un total de 520000 kg de acero y 4545,14 m3 de concreto.
     
    The Mario Santo Domingo building is located at kilometer 5 via Puerto Colombia within the facilities of the Universidad del Norte. This building aims to meet the need to increase the physical plant of said university. The construction system of the proposal is based on moment-resistant load-bearing walls with the capacity to resist the axial load demanded by the use and constitution of the building, in addition to a non-moment-resistant frame that is capable of transmitting loads to the foundation. The system was designed for a moderate DMO energy dissipation capacity, and assuming an intermediate seismic hazard zone, using the coefficient data that represents the acceleration and effective peak horizontal velocity corresponding to the city of Santa Marta. For the analysis of the seismic load, the seismic weight of all the elements of the structure and the horizontal forces that would be caused by an eventual earthquake were calculated, and it was determined that the structure is capable of dissipating 7.8% of its weight. In total, the structure requires a total of 520000 kg of steel and 4545,14 m3 of concrete.
     
    Colecciones a las que pertenece
    • Proyectos finales Pregrado en Ingeniería Civil y Ambiental [149]
    Imagen-PF-español.jpeg (218.4Kb)
    Image-PF-english.jpeg (219.5Kb)
    SIStema estructural basado en muros de carga (1).pdf (281.8Kb)Visualizar
    SIStema estructural basado en muros de carga (2).pdf (281.9Kb)Visualizar

    DSpace software copyright © 2002-2016  DuraSpace
    Contacto | Sugerencias
    Theme by 
    Atmire NV
     

     

    Listar

    Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

    Mi cuenta

    AccederRegistro

    DSpace software copyright © 2002-2016  DuraSpace
    Contacto | Sugerencias
    Theme by 
    Atmire NV