• Login
    Ver ítem 
    •   DSpace Principal
    • División Ingenierías
    • Departamento de Ingeniería Civil y Ambiental
    • Proyectos finales Pregrado en Ingeniería Civil y Ambiental
    • Ver ítem
    •   DSpace Principal
    • División Ingenierías
    • Departamento de Ingeniería Civil y Ambiental
    • Proyectos finales Pregrado en Ingeniería Civil y Ambiental
    • Ver ítem
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Diseño taller de mecánica diesel - sistema aporticado con viguetas nervadas en 1 dirección

    2. Design of diesel mechanics workshop – moment frame system with one-way ribbed slabs

    • Exportar citas
      • Exportar a Refworks
      • Exportar a Ris
      • Exportar a Endnote
      • Exportar a Mendeley
    URI
    http://hdl.handle.net/10584/13581
    Registro completo
    Mostrar el registro completo del ítem
    Autor
    Fernández Guerra, Daniela
    Mejía Mejía, María Paula
    Zapata Visbal, Julio Andrés
    Fecha
    2025-05-30
    Resumen
    El proyecto responde a la necesidad de brindar a la empresa ElectroDiesel una edificación de tipo comercial, segura y funcional, que cumpla con los requerimientos de diseño dados por la NSR-10 para zonas de amenaza sísmica intermedia como El Rodadero, Magdalena. Para ello, se evaluaron diferentes sistemas estructurales y de cimentación. Debido a la exigencia dada por el nivel de amenaza sísmica, para resistir las cargas verticales y laterales se eligió un sistema de pórticos resistentes a momento con capacidad de disipación de energía moderada (DMO), un sistema de entrepiso de viguetas armadas en una dirección y cimentaciones puntuales de tipo zapata conectadas con vigas de amarre. Además, se consideraron los criterios económicos y técnicos de resistencia y estabilidad descritos por la normativa NSR-10. El diseño contempla un sistema de losa aligerada, vigas, columnas, muro de contención, zapatas, escaleras y elementos de amarre. La cimentación está adaptada a un tipo de suelo D, utilizando zapatas concéntricas que aseguran la estabilidad de la estructura. Se siguen los lineamientos de la NSR-10, NIST GCR 16-917-40 y AIS 114-17, con el fin de verificar el cumplimiento de los requerimientos, tales como el concepto de columna fuerte-viga débil. Se aplicaron espectros de aceleración y se diseñaron elementos resistentes a flexión, cortante y punzonamiento. También se analizó la estabilidad del muro de contención frente a volcamiento, deslizamiento y capacidad portante, con factores de seguridad que cumplen con los mínimos requeridos. Finalmente, el proyecto integra soluciones estructurales eficientes y adaptadas al contexto sísmico de la región, asegurando una edificación funcional, confiable y alineada con los más altos estándares técnicos y reglamentarios.
     
    The project addresses the need to provide the company ElectroDiesel with a commercial building that is safe, functional, and compliant with the design requirements established by the NSR-10 for zones of intermediate seismic hazard, such as El Rodadero, Magdalena. To achieve this, various structural and foundation systems were evaluated. Due to the seismic demand in the area, a moment-resisting frame system with moderate energy dissipation capacity (DMO) was selected to withstand vertical and lateral loads, along with a one-way ribbed slab floor system and isolated footing foundations connected by tie beams. Additionally, both economic and technical criteria regarding strength and stability, as outlined in the NSR-10, were taken into account. The design includes a system of lightweight slabs, beams, columns, retaining wall, footings, stairs, and tie elements. The foundation is adapted to a type D soil profile, using concentric footings that ensure the structural stability. The project follows the guidelines of the NSR-10, NIST GCR 16-917-40, and AIS 114-17, in order to verify compliance with requirements such as the strong column–weak beam principle. Acceleration spectra were applied, and elements were designed to resist bending, shear, and punching. The stability of the retaining wall was also analyzed against overturning, sliding, and bearing capacity, with safety factors that meet the minimum regulatory thresholds. Finally, the project integrates efficient structural solutions tailored to the seismic context of the region, ensuring a functional and reliable building aligned with the highest technical and regulatory standards.
     
    Colecciones a las que pertenece
    • Proyectos finales Pregrado en Ingeniería Civil y Ambiental [233]
    Imagen representativa PF-ESTRUCTURAS GR 02 (2).png (10.77Mb)
    Imagen representativa PF-ESTRUCTURAS GR 02.pdf (667.9Kb)Visualizar
    Imagen representativa PF-ESTRUCTURAS GR 02 (3).png (10.80Mb)
    Imagen representativa PF-ESTRUCTURAS GR 02 (2).pdf (668.1Kb)Visualizar

    DSpace software copyright © 2002-2016  DuraSpace
    Contacto | Sugerencias
    Theme by 
    Atmire NV
     

     

    Listar

    Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

    Mi cuenta

    AccederRegistro

    DSpace software copyright © 2002-2016  DuraSpace
    Contacto | Sugerencias
    Theme by 
    Atmire NV