TY - JOUR AU - Corredor, Lesmes AU - Durango, Néstor AU - Arturo, González AU - Castro Cantillo, Franky D AU - López Muñoz, Giovanny A AU - Miranda Rada, Moisés R AU - Restrepo Cueto, Alfredo J PY - 2020 UR - http://hdl.handle.net/10584/8934 AB - La planta térmica Termonorte se encuentra en el departamento de Magdalena, cuenta con 10 motores con una capacidad de 9.3 MW cada uno, para un total de 93 MW. La planta hace parte de la red nacional funcionando bajo cargo por confiabilidad, por lo que... AB - The Termonorte thermal plant is located in the department of Magdalena, has 10 engines with a capacity of 9. 3 MW each, for a total of 93 MW. The plant is part of the national grid and operates under a reliability charge, so a certain level of... LA - eng PB - Barranquilla, Universidad del Norte, 2020 KW - Caida de presion KW - Pressure drop KW - ORC KW - Intercambiador de calor KW - Heat exchanger KW - ORC TI - Design of a heat recovery system for power generation from dual fuel engines by implementing an ORC system ER -