Mostrar el registro sencillo del ítem

Monitoring environmental and electrical variables for a medical center in a Non-interconnected zone

dc.contributor.advisorCalle Torres, María Gabriela
dc.contributor.advisorCastillo Sierra, Rafael de Jesús
dc.contributor.authorJaramillo Durango, Ernesto Daniel
dc.contributor.authorRosa Rondon, Jaider Andrés de la
dc.date.accessioned2024-06-11T15:37:15Z
dc.date.available2024-06-11T15:37:15Z
dc.date.issued2024-05-31
dc.identifier.urihttp://hdl.handle.net/10584/11952
dc.description.abstractEste proyecto se basa en el diseño e implementación de un sistema de monitoreo ambiental y eléctrico para un centro médico en zona no interconectada (sin comunicaciones). El uso de tecnologías de la información y su integración con el día a día con el internet de las cosas es cada vez más amplio. Para este caso en particular, se centra en medir las variables ambientales de velocidad del viento, humedad, temperatura, luminosidad exterior y la temperatura y humedad de la nevera de medicamentos. Asimismo, se requiere medir las variables eléctricas de Voltaje, Corriente y potencia de la energía regenerada por el panel solar. Esta extracción de datos y viables medidas se logró de forma, al igual que su transmisión en un rango de 7km. Las medidas se compararon con medidores comerciales, obteniendo que el máximo error porcentual en las medidas comparadas fue del 6%. Las variables se pueden visualizar en su interfaz gráfica EcoMedix Guard, Al igual que sus históricos que se muestran en tablas o gráficas. Además, es posible descargar esta información en caso de que se quiera realizar algún tratamiento de datos.es_ES
dc.description.abstractThis project is based on the design and implementation of an environmental and electrical monitoring system for a medical center in a non-interconnected zone (without communications). The use of information technologies and their integration into daily operations with the Internet of Things is becoming increasingly widespread. For this particular case, the focus is on measuring environmental variables such as wind speed, humidity, temperature, and external luminosity, as well as the temperature and humidity of the medication refrigerator. Additionally, it is necessary to measure electrical variables such as voltage, current, and power generated by the solar panel. This data extraction and viable measurements were achieved effectively, along with their transmission over a range of 7 km. The measurements were compared with commercial meters, showing that the maximum percentage error in the compared measurements was 6%. The variables can be visualized on the EcoMedix Guard graphical interface, as well as their historical data displayed in tables or graphs. Additionally, it is possible to download this information for further data processing if needed.es_ES
dc.language.isospaes_ES
dc.publisherBarranquilla, Universidad del Norte, 2024es_ES
dc.rightsUniversidad del Nortees_ES
dc.subjectMonitoreoes_ES
dc.subjectLoRaes_ES
dc.subjectElectricases_ES
dc.subjectAmbientaleses_ES
dc.subjectZona no interconectadaes_ES
dc.subjectMonitoringes_ES
dc.subjectElectricales_ES
dc.subjectEnvironmentales_ES
dc.subjectNon-Interconnected Zonees_ES
dc.titleMonitoreo de variables ambientales y eléctricas para centro médico en zona no interconectadaes_ES
dc.titleMonitoring environmental and electrical variables for a medical center in a Non-interconnected zoneen_US
dc.typearticlees_ES
dc.rights.accessRightsopenAccesses_ES


Ficheros en el ítem

No Thumbnail [100%x80]
No Thumbnail [100%x80]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem