Design of a hybrid trigeration system and conceptual scheme of a the machinery of a cooling district for Hospital Universidad del Norte (HUN)

dc.contributor.advisorCaballero FLorez, Hugo Cesar
dc.contributor.advisorCorredor Martinez, Lesmes Antonio
dc.contributor.authorOchoa Valest, Andrea Helena
dc.contributor.authorRey Haggar, Arturo
dc.contributor.authorToncel Armado, Aramis Alexander
dc.contributor.authorTrejo Diaz, Leidy Johana
dc.date.accessioned2019-06-14T03:15:57Z
dc.date.available2019-06-14T03:15:57Z
dc.date.issued2019-05-24
dc.identifier.urihttp://hdl.handle.net/10584/8535
dc.description.abstractUna de las problemáticas del país es la falta de confiabilidad por parte de las redes eléctricas, lo cual afecta diferentes sectores como vivienda, industria y comercio. Lo que conlleva a buscar diferentes alternativas de generación de energía superior y más confiable. En este proyecto, se busca diseñar un sistema confiable y al mismo tiempo, económico, para suplir las necesidades energéticas del Hospital de la Universidad del Norte. Fue requerido diseñar un sistema de trigeneración híbrida que logre disminuir el costo mensual de consumo eléctrico por parte del hospital. Se busca que este proyecto sea viable económicamente a corto plazo. Dicho sistema consta de un motor a gas CG132-8 que con sus gases de escape alimenta a un enfriador por absorción Broad BEY20 para suplir una parte de la demanda térmica. Por otro lado, se tienen paneles solares N330, que logran suplir completamente la demanda eléctrica del hospital. Gracias a esto, se logra cumplir el objetivo de disminuir el costo mensual eléctrico. Este proyecto tiene un retorno de inversión de siete (7) años y (7) meses. La hibridación del sistema es un incentivo de inversión para personas o entidades que apuntan a este tipo de energías y que con esto encuentren un atractivo en dicho proyecto.es_ES
dc.description.abstractOne of the main issues of the country is the lack of reliability on the part of the electricity grids, which affects different sectors such as housing, industry and commerce. Which leads to look for different alternatives for generating superior and more reliable energy. In this project, the aim is to design a reliable and at the same time economic system to supply the energy needs of the Hospital de la Universidad del Norte It was required to design a hybrid trigeneration system that manages to reduce the monthly cost of electricity consumption by the hospital. It is intended that this project is economically viable in the short term. This system consists of a gas engine CG132-8 that with its exhaust gases feeds a Broad BEY20 absorption cooler to supply a part of the thermal demand. On the other hand, there are N330 solar panels, which completely replace the electrical demand of the hospital. Thanks to this, the objective of decreasing the monthly electric cost is achieved. This project has an investment return of seven (7) years and seven (7) months. The hybridization of the system is an investment incentive for people or entities that aim at this type of energy and that with this, they can find an attraction in said project.en_US
dc.language.isospaes_ES
dc.publisherBarranquilla, Universidad del Norte, 2019es_ES
dc.rightsUniversidad del Nortees_ES
dc.subjectHibridaciónes_ES
dc.subjectMotor a gases_ES
dc.subjectEnfriador por absorciónes_ES
dc.subjectRetorno de inversiónes_ES
dc.subjectGas naturales_ES
dc.subjectHybridizationen_US
dc.subjectGas engineen_US
dc.subjectAbsorption coolingen_US
dc.subjectReturn on investmenten_US
dc.subjectNatural gasen_US
dc.titleDiseño de un Sistema de Trigeneración Hibrido y un Esquema Conceptual de la maquinaria para una Central de Frío Del Hospital Universidad Del Norte (HUN)es_ES
dc.titleDesign of a hybrid trigeration system and conceptual scheme of a the machinery of a cooling district for Hospital Universidad del Norte (HUN)en_US